TM 9-2320-209-34-2-2
FRAME 2
NOTE
Readings must be within limits given in table 17-6.
If readings are not within given limits, throw away
part and get a new one.
1.
Measure fit of bearing (1) on shaft (2).
GO TO FRAME 3
Table 17-6. Power Leveler Assembly Wear Limits
Size and Fit
Index of New Parts Wear Limit
Number
Item /Point of Measurement
(inches) (inches)
1 and 2 Fit of bearing on shaft
0.001
to
0.005
None
17-618