TM 9-2320-209-34-2-3
a.
Primary Van Body Personnel Heater.
(1) 24-volt test.
(a) Bleeding fuel line.
FRAME 1
Soldiers
1.
Open van doors and mount access ladder. Refer to
A and B
TM 9-2320-209-10.
Soldier A
2.
Turn shut-off cock (1) to ON position. Tell soldier B when ready.
Soldier B
3.
Turn power converter selector switch (2) to 24 VOLT position.
4. Loosen line connector (3).
5. Turn heater switch (4) to START position.
6. Turn heater switch (4) to OFF position when fuel starts to drip
from fuel line (5).
7. Tighten line connector (3).
GO TO FRAME 2
21-103