(2) 115-volt test.
(a) Bleeding fuel lines.
FRAME 1
1.
Connect 115-volt line.
Refer to TM 9-2320-209--10.
Soldier A 2.
Turn shut-off cock (1) to ON position. Tell soldier B when
ready.
Soldier B 3.
Turn power converter selector switch (2) to 115-VOLT position.
4.
Loosen line connector (3).
5.
Turn heater switch (4) to START positior.
.
6.
When fuel starts to drip from fuel line (5) turn heater switch
(4) to OFF position.
7.
Tighten line connector ( 3).
GO TO FRAME 2
21-107