TM-9-2320-209-34-2-3

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; MAINTENANCE; DIRECT SUPPORT AND GENERAL SUPPORT LEVEL; VOLUME 2 OF 2; PART 3 OF 3

MAY 1981

  TM-9-2320-209-34-2-3 - Page 446 of 592

TM 9-2320-209-34-2-3
b. Secondary Van Body Personnel Heater.
(1) 24-volt test.
(a) Bleeding fuel line.
FRAME 1
I
Soldiers 1.
A and B
Soldier A 2.
Solder B 3.
4.
5.
6.
7.
GO TO FRAME
Open van doors and mount access ladder. Refer to
TM 9-2320-209-10.
Turn shut-off cock (1) to ON position. Tell
Turn power converter selector switch (2) to
Loosen line connector (3).
Turn heater switch (4) to START position.
Turn heater switch (4) to OFF position when
from fuel line (5) .
Tighten line connector (3) .
2
soldier B when ready.
24-volt position.
fuel starts to drip
21-111


Back to Top