3-84. TOP STOP INJECTOR PLUNGER TRAVEL ADJUSTMENT (Contd)
14. Push "i/m” (inch/millimeter) selector button (2) on digimatic indicator (1) until “in” is displayed.
NOTE
l To use U.S. customary values, the display on the digimatic
indicator must display
and ‘in”.
l To use metric values, the display on the digimatic indicator must
display “$” and “mm”.
15. Push direction selector button (3) on digimatic indicator (1) until”~ is displayed.
16. Press PSET button (4) sand enter the top stop setting fixture preset value using numbered key (6) on
digimatic presetter (5). Ensure a “P’ is indicated on digimatic indicator.
NOTE
Preset values must be indicated on digimatic indicator before pre-
ceding with plunger travel setting or an incorrect reading will be
taken for the plunger travel.
17. Press LOAD button (7) and wait 5 seconds or until the digimatic indicator (1) displays preset .
readings.