3-84. TOP STOP INJECTOR PLUNGER TRAVEL ADJUSTMENT (Contd)
8. Install holding bracket on fuel supply grooves (3) of fuel injector (1).
9. Install injector plunger link on fuel injector (1).
10.
Install fuel injector (1) on top stop setting fixture and center over stopnut (2). Using crows foot,
tighten stopnut (2) 115 in.-lb (13 N•m).
11. Turn two clamp handles (4) down to release deadweights.
12. Place deadweights switch (5) in LOWER position.
13. Place plunger switch (6) in LOAD position.
3-252