TM-9-2320-260-34-2

TRUCK, 5-TON, 6X6, M809 SERIES (DIESEL)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; VOLUME 2 OF 2

JULY 1994

  TM-9-2320-260-34-2 - Page 361 of 863

TM 9-2320-260-34-2
15-82. LOAD CENTER MAINTENANCE (Contd)
CAUTION
Safety wire will be used to route converter and auxiliary pump
wiring harness and entrance receptacle wiring harness through
van body. Connect safety wire to wiring harness with electrical
tape.
NOTE
Perform steps 28 and 29 for M820 and M820A2 vehicles.
28. Remove six screws (3) and wires (4) from two 20-amp circuit breakers (2).
29. Remove converter and auxiliary pump wiring harnesses (5) from load center (1).
30. Remove setscrew (11) and wire (12) from neutral bar (7).
31. Remove three setscrews (9) and wires (10) from 100-amp circuit breaker (8).
32. Remove entrance receptacle wiring harness (6) from load center (1).
15-300