GOVERNOR FILTER REMOVAL
WARNING
Solvent cleaning compound is flammable and will not be used near open flame. Use only in
well-ventilated areas. Failure to comply may result in injury or death to personnel.
1.
Remove governor filter plug (Figure 5, Item 1) and o-ring (Figure 5, Item 2) from transmission
(Figure
5,
Item
3). Discard o-ring and clean plug thoroughly with solvent cleaning compound.
CAUTION
Do not pry governor filter from governor filter housing. Use thin, pliable wires as a hook to
reach into the housing to slide out filter. Failure to do this will result in governor filter
housing
damage.
2.
Remove governor filter (Figure 5, Item 4) from governor filter housing (Figure 5, Item 3). Discard filter.
TM 9-2320-272-23-3
0362