INSTALLATION
1.
Connect lead (Figure 2, Item 18) to connector (Figure 2, Item 19).
2.
Install wires (Figure 2, Items 24 and 25) on starter solenoid (Figure 2, Item 21) with lockwasher
(Figure
2,
Item
22) and nut (Figure 2, Item 23).
3.
Connect leads (Figure 2, Items 10 and 12) to circuit breaker (Figure 2, Item 11).
4.
Connect lead (Figure 2, Item 16) to high-beam selector switch (Figure 2, Item 17).
5.
Install lead (Figure 2, Item 27) and relay (Figure 2, Item 7) on firewall (Figure 2, Item 9) with two lockwashers
(Figure 2, Item 13) and screws (Figure 2, Item 14).
6.
Install four leads (Figure 2, Items 2, 8, 15, and 27) on relay (Figure 2, Item 7) with clips (Figure 2, Item 5) and
screws (Figure 2, Item 4).
NOTE
Assistant will help with Step (7).
7.
Install grommet (Figure 2, Item 6) and retainer (Figure 2, Item 28) on firewall (Figure 2, Item 9) with two
lockwashers (Figure 2, Item 31), washers (Figure 2, Item 30), and screws (Figure 2, Item 29).
8.
Pull leads (Figure 2, Items 1 and 2) through hole in firewall (Figure 2, Item 9).
9.
Install tiedown strap (Figure 2, Item 26) on front main wiring harness (Figure 2, Item 20) and leads
(Figure
2,
Items
16
and
19).
10.
Connect leads (Figure 2, Items 1 and 2) to warning light switch (Figure 2, Item 3).
TM 9-2320-272-23-5
0804
0804-4