TM-9-2320-273-20

TRUCK TRACTOR, LINE HAUL; LIGHT EQUIPMENT TRANSPORTER; TRUCK CHASSIS; MEDIUM EQUIPMENT TRANSPORTER

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE

NOVEMBER 1980

  TM-9-2320-273-20 - Page 428 of 1500

TM 9-2320-273-20
5-6. TEST EQUIPMENT (Continued).
(2)
TS-352 B/U
(a)
Set FUNCTION switch (1) to DIRECT (range switch can be at any position).
(b)
Put black lead in “DC/* AC/OHMS” jack (2).
(c)
To measure 24 volts dc, plug red lead into “50V” jack on left side of meter (3).
(If measuring less than 10 volts dc, use “10V” jack, If measuring less than 2.5
volts dc, use “2.5V” jack.)
Figure 5-11. Setting the Function Switch TS-352
B/U
(3) SIMPSON 160
(a)
Connect black lead to COM- jack.
(b) Connect red lead to+ jack.
(c)
T
O
measure 24 volts dc, set selector switch to V/DC 50 position. (If measuring
less than 10 volts dc, set selector switch to V/DC 10 position. If measuring less
than 2.5 volts dc, set selector switch to V/DC 2.5 position. )
Figure 5-12. Setting the Function Switch Simpson 160
TA
074698
5-12


Back to Top