TM-9-2320-279-10-2

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

OPERATOR’S MANUAL VOLUME 2 OF 2

DECEMBER 1998
CHANGE 3

  TM-9-2320-279-10-2 - Page 114 of 819

TM 9-2320-279-10-2
M984E1 General Operating Procedures (Cont)
WARNIN G
Stand clear of outrigger beams while operating lever or
injury could result when beams come out.
NOTE
Always operate control levers with light, even
pressure.
Outrigger beams will come out slower with light
pressure on lever. Pushing lever to full travel will
cause faster movement.
(9)
Move O/R EXT lever (11) to IN position briefly and lift and turn left
outrigger lockpin (12) to unlock position.
(10)
Move O/R EXT lever (11) to OUT position until left outrigger beam (13)
is fully extended.
2-79


Back to Top