TM-9-2320-279-10-2

M977 SERIES, 8x8 HEAVY EXPANDED MOBILITY TACTICAL TRUCKS (HEMTT)

OPERATOR’S MANUAL VOLUME 2 OF 2

DECEMBER 1998
CHANGE 3

  TM-9-2320-279-10-2 - Page 114 of 819

TM 9-2320-279-10-2
M984E1 General Operating Procedures (Cont)
WARNIN G
Stand clear of outrigger beams while operating lever or
injury could result when beams come out.
NOTE
●
Always operate control levers with light, even
pressure.
●
Outrigger beams will come out slower with light
pressure on lever. Pushing lever to full travel will
cause faster movement.
(9)
Move O/R EXT lever (11) to IN position briefly and lift and turn left
outrigger lockpin (12) to unlock position.
(10)
Move O/R EXT lever (11) to OUT position until left outrigger beam (13)
is fully extended.
2-79