(4) Emor Readout.
EOO1 is a typical error readout. There are 17 different error readouts, all starting
with E. An error readout warns that the transducer was not connected, wrong test number was entered,
engine failed to start, etc. All of the error messages mean the problem must be corrected before continuing
testing. The error messages are described in !Ihble 2-14. If an error message does not go away after
corrective action, refer to TM 9-4910-571-12&P for error message fault isolation.
n
m
TA356834
(5)
Confidence Error Readouts. CO04
is a typical confidence error readout resulting from the
detection of a faulty VTM during confidence test. There are 44 of these codes. They are used by the DS
Repairman as an aid in repairing a faulty VTM.