(2)
Loosen screw (3) and remove plug (4)
and seal (5).
(3)
Remove plug (6) and preformed
packing (7).
TM 9-2320-279-34-3
M977, M985, and M984E1 Crane Maintenance Instructions (Cont)
(4)
Put crane in operating condition
(TM 9-2320-279-10).
CAUTION
Do not operate crane with boom below
horizontal when there is a load on hook.
(5)
Attach crane hook (8) to an
immovable object (9).
(6)
While operating HOIST control
lever (10) UP, adjust
internal screw (11) until gage reads
between 1900 psi (13 100 kPa) and
2100 psi (14 480 kPa) for M977 or
between 2100 psi (14 480 kPa) and
2300 psi (15 858 kPa) for M985.
Change 3
17-115