. 400 AMPERE DUAL VOLTAGE ALT±E±R±N±ATOR (12469057) TESTING AND REPAIR (Cont'd)
TM 9-2320-280-34
Change 1
6 - 4 4 . 1 7
26.
Perform regulator bypass test. Prepare alternator as in full-load test.
NOT E
• Perform this test only when instructed from tables 6-H and 6-I.
• Use jumper wire rated for 15 amps.
27.
Disconnect alternator connector from regulator. With alternator spinning, use jumper wire and short
pin A to ground momentarily. Record results.
28.
Amperage should rise within ±10 percent of rated value with jumper wire connected, and fall with
jumper disconnected. Refer to table 6-K, Regulator Bypass Test, for diagnosis.
CONNECT
DISCONNECT
DIAGNOSIS
AMPS RISE
AMPS FALL
Alternator OK. Replace regulator only if low
AMPS (160-238)/low VOLTS (21-25) are
indicated in table 6-H and/or table 6-I.
NO CHANGE
NO CHANGE
Alternator must be repaired. Refer to static
testing, task c.
Table 6-K. Regulator Bypass Test.
29.
Turn test stand master power switch and load switch to OFF.
30.
Disconnect jumper wires from terminals on test stand and alternator.
31.
Remove belt from test stand pulley and alternator pulley. Remove alternator from test stand.