TROUBLESHOOTING.
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
20 STARTER FAILS TO OPERATE (Continued).
8
Check for voltage at
24-volts dc
Go to step 9
Replace neutral
circuit 47A-TN terminal nominal
safety switch
of neutral
(para 3-106).
safety switch.
9
Check for voltage at
24-volts dc
Go to step 10
Repair circuit
circuit 47B-TN terminal nominal
47B-TN and/or
of starter
47A-TN (para
relay
3-127).
NOTE
With positive lead on circuit 47B-TN, check ground with
negative lead when doing the following checks.
10
Check for voltage at
24-volts dc
Go to step 11
Tighten and/or
circuit 98F-BK ground
nominal
clean connection.
point of instrument
panel.
11
Check for voltage at
24-volts dc
Go to step 12
Repair circuit
circuit 98F-BK terminal- nominal
98F-BK (para
of start switch
3-127).