TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
20.
STARTER FAILS TO OPERATE (Continued).
NOTE
With positive lead on circuit 46E-BR, check ground with negative leads when doing the following checks.
17
Check for voltage at
24-volts dc
Go to step 18
Refer to mal-
starter motor main
nominal
function 18.
battery ground
connection.
18
Check for voltage at
24-volts dc
Go to step 19
Repair, clean,
starter motor solenoid
nominal
or tighten
ground connection
ground cable
noid ground
terminal and
starter motor
ground stud.
19
Release and depress
Starter
Starting
Replace starter
start switch
cranks
system OK
motor (para
2-58