TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
20.
STARTER FAILS TO OPERATE (Continued).
NOTE
The start switch must be pushed and held when doing steps 12 thru 18.
12
Check for voltage at
24-volts dc
Go to step 13
Replace switch
circuit 46-BR terminal
nominal
(para 3-75).
of start switch.
13
Check for voltage at
24-volts dc
Go to step 14
Repair circuit
circuit 46-BR terminal
nominal
46-BR (para
of starter relay
3-127).
14
Release and depress
Starter relay
Go to step 15
Replace starter
start switch
should oper-
relay (para
ate (clicking
3-115).
sound).
NOTE
With negative lead on a good chassis or body ground, use positive lead when doing the following checks.
15
Check for voltage at
24-volts dc
Go to step 16
Replace starter
circuit 46D-BR terminal
nominal
relay (para
of starter relay
3-115).
16
Check for voltage at
24-volts dc
Go to step 17
Repair circuits
circuit 46E-BR terminal
nominal
46E-BR and/or
of starter motor
46D-BR (para
solenoid
3-127).
2-56