TM 9-2320-283-20-1
TOUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
82.
ELECTRICAL HORN NOT WORKING.
NOTE
Blackout toggle switch must be set to NORMAL position when doing the following
checks.
1.
Remove circuit breaker
bracket far enough to
access circuit breaker
CB-5 (para 3-114), and
go to step 2.
2.
Check for voltage at
12-volts dc
Go to step 3.
Reset circuit
circuit 35-LG or 42-LG
nominal.
breaker CB-5
terminal of circuit
and/or trouble-
breaker CB-5.
shoot CB-5
circuit.
(Refer
to malfunction
34).
3.
Check for voltage at
12-volts dc
Go to step 4.
Repair circuit
circuit 35-LG terminal
nominal.
35-LG (para
of blackout toggle
3-127).
Install
switch.
circuit breaker
bracket (para
3-114).
4.
Remove relay RY-1 (para
3-112), and go to step
5.
2-266