TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
82.
ELECTRICAL HORN NOT WORKING (Continued).
10. Install relay RY-1
(para 3-112), and go
to step 11.
11. Disconnect horn (para
3-117), and go to step
12.
12. Move blackout toggle
Listen for
Install circuit
Replace relay
switch from NORMAL to
clicking
breaker bracket
RY-1.
Install
BLACKOUT and back to
sound at
(para 3-114),
circuit breaker
NORMAL position.
relay RY-1.
and go to step
bracket (para
13.
3-112 and
3-114).
Connect
horn (para
3-117).
13. Disconnect circuit
41-WH from 41A-WH at
connector, and go to
step 14.
14. Check for voltage at
12-volts dc
Connect engine
Repair circuit
circuit 41-WH (pin 17
nominal.
harness con-
41-WH (para
of connector).
nector, and go
3-127).
Connect
to step 15.
horn (para
3-117).
15. Check for voltage at
12-volts dc
Replace horn
Repair circuit
circuit 41A-WH ter-
nominal.
(para 3-117).
41A-WH (para
minal of horn.
3-127).
2-270