TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
83.
PERSONNEL HEATER FAN MOTOR NOT WORKING.
NOTE
Make sure ignition switch is in ON position and heater fan switch is set
at speed being tested when doing the following checks.
If any speed is working, begin with step 3.
1.
Remove circuit breaker
bracket far enough to
access circuit breaker
CB-4 (para 3-114), and
go to step 2.
2
Check for voltage at
12-volts dc
Install circuit
Reset circuit
circuit 76-DB terminal
nominal.
breaker panel
breaker CB-4
of circuit breaker
(para 3-114),
and/or trouble-
CB-4.
and go to step
shoot CB-4 cir-
3.
cuit.
(Refer
to malfunction
33).
3.
Check for voltage at
12-volts dc
Go to step 4.
Repair circuit
circuit 76-DB terminal
nominal.
76-DB (para
of heater fan switch.
3-127).
4.
Check for voltage at
12-volts dc
Replace person-
Replace heater
LOW, MED, and HIGH
nominal.
nel heater
fan switch
terminals of heater fan
motor (para
(para 3-81).
switch.
3-299).
2-272