TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
89.
LEFT SIDE UTILITY OUTLET RECEPTACLE NOT WORKING.
NOTE
It is assumed here that right side utility outlet receptacle is OK.
1.
Remove trim panel far
enough to access
utility outlet recep-
tacle (para 3-276), and
go to step 2.
2.
Check for voltage at
12-volts dc
Go to step 3.
Repair circuit
circuit 21B-PP terminal
nominal.
21B-PP (para
of utility outlet
3-127).
Install
receptacle.
trim panel
(para 3-276).
2-283