TROUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
NOTE
With positive lead on circuit 21BPP, check ground with negative lead
when doing the following checks.
3.
Check for ground at
12-volts dc
Replace work-
Repair circuit
circuit 99D-BK terminal
nominal.
lamp receptacle
99D-BK (para
of utility outlet
(para 3-132).
3-127).
receptacle.
90.
BOTH UTILITY OUTLET RECEPTACLES NOT WORKING.
1.
Remove circuit breaker
bracket far enough to
access circuit breaker
CB-6 (para 3-114), and
go to step 2.
2.
Check for voltage at
12-volts dc
Install circuit
Reset circuit
circuit 21-PP terminal
nominal.
breaker bracket
breaker CB-6
of circuit breaker
(para 3-114),
and/or trouble-
CB-6.
and go to step
shoot CB-6
3.
circuit.
(Refer
to malfunction
34).
3.
Disconnect circuit
21-PP from 21A-PP
(located behind instru-
ment gages), and go to
step 4.
4.
Check for voltage at
12-volts dc
Connect circuit
Repair circuit
circuit 21-PP terminal
nominal.
21-PP to
21-PP (para
of connector.
21A-PP, and go
3-127).
to step 5.
2-284


Back to Top