TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11. TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
90.
BOTH UTILITY OUTLET RECEPTACLES NOT WORKING (Continued).
5.
Remove right side trim
panel far enough to
access utility outlet
receptacle (para
3-276), and go to step
6.
6.
Check for voltage at
12-volts dc
Go to step 7.
Repair circuit
circuit 21A-PP terminal
nominal.
21A-PP (para
of utility outlet
3-127).
Install
receptacle.
trim panel
NOTE
With positive lead on circuit 21APP (or suitable
12volt
power
lead), check
ground with negative
lead when doing the following checks.
7.
Check for voltage at
12-volts dc
Go to step 8.
Clean and
circuit 98F-BK ground
nominal.
tighten ground
point of instrument
point
connec-
panel.
tions.
Install
trim panel
(para 3-276).
2-286