TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1106 of 1318

TM 9-2320-328-13&P-1
0102-4
DRAFT
0102
Change 1
.
HWT0552
.
Step 4.
Install circuit breaker FS 13 (WP 0242).
Remove cab instrument panel C (WP 0205).
Disconnect cab instrument panel wire harness EMERG MASTER switch connector.
Push battery disconnect switch to on position (WP 0007).
Turn Service Drive Lights On
(TM 9-2320-422-10).
Check for 22 to 28 VDC between cab instrument panel wire
harness wire 1623 (yellow) at EMERG MASTER switch connector, terminal 5 and a
known good ground.
.
If 22 to 28 VDC are present, go to Step 6.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top