TM 9-2320-328-13&P-1
0101-2
DRAFT
0101
HWT0503
Step 1.
Push battery disconnect switch to on position (WP 0007).
If system air pressure is
below 85 psi (586 kPa), start engine and allow system air pressure to build to at least
85 psi (586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
Put
cab FOAM SYSTEM switch to on position (WP 0004). Open pump house access door
assembly (WP 0009).
While an assistant puts cab UNDER TRUCK NOZZLES switch
to on position (WP 0004), check if under truck nozzles foam metering valve operates to
open position.
If under truck nozzles foam metering valve does not operate to open
position, troubleshoot Under Truck Nozzles Do Not Operate When Selected
(WP 0077).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION