TM 9-2320-328-13&P-1
0100-4
DRAFT
0100
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT0701
Step 4.
Push battery disconnect switch to on position (WP 0007).
Put pump operator’s panel
TANK TO PUMP switch to OPEN position (WP 0004).
Check for 22 to 28 VDC between
pump operator’s panel wire harness wire 2855 (red) from pump operator’s panel TANK
TO PUMP indicator to a known good ground.
a.
If 22 to 28 VDC are present, replace TANK TO PUMP
indicator (WP 0213).
b.
If 22 to 28 VDC are not present, repair wire 2855 in pump operator’s
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION