TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1087 of 1318

TM 9-2320-328-13&P-1
0098-5/(6 blank)
DRAFT
0098
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT0733
Step 4.
Push battery disconnect switch to on position (WP 0007).
Put WATER TANK DRAIN
switch to OPEN position (WP 0004).
Check for 22 to 28 VDC between pump operator’s
panel wire harness wire 4053 (brown) at WATER TANK DRAIN indicator and a known
good ground.
Put pump operator’s panel WATER TANK DRAIN switch to CLOSED
position (WP 0004).
Pull battery disconnect switch to off position (WP 0007).
Connect
pump house wire harness water tank drain control valve connector.
a.
If 22 to 28 VDC are present, replace pump operator’s panel WATER
TANK DRAIN indicator (WP 0213).
b.
If 22 to 28 VDC are not present, repair wire 4053 in pump operator’s
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top