Step 16.
Check for continuity across pump operator’s panel wire harness wire 2773 (red) from
DRIVER MAIN INLET PRIMER button terminal to primer pump inline fuse terminal.
If there is no continuity, repair wire 2773 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION