TM 9-2320-328-13&P-1
0097-10
DRAFT
0097
HWT0691A
Step 13.
Pull battery disconnect switch to off position (WP 0007).
Open pump operator’s
panel (WP 0207).
Disconnect pump operator’s panel wire harness pump hot audio
alarm connector (WP 0203).
Check for continuity across pump operator’s panel wire
harness wire 1405 (blue) from PUMP HOT PUSH TO TEST button, terminal to pump
hot audio alarm connector, terminal B.
If there is no continuity, repair wire 1405 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0303).
Step 14.
Check for continuity across pump operator’s panel wire harness wire 3895 (black) from
pump hot audio alarm, terminal A to a known good ground.
a.
If there is continuity, replace pump hot audio alarm (WP 0203).
b.
If there is no continuity, repair wire 1405 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION