TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1084 of 1318

TM 9-2320-328-13&P-1
0098-2
DRAFT
0098
HWT0730
Step 1.
Remove pump house panel K (WP 0339).
Disconnect pump house wire harness water
tank drain control valve connector.
Push battery disconnect switch to on position
(WP 0007).
Put pump operator’s panel WATER TANK DRAIN switch to OPEN position
(WP 0004).
With a test lead set, check for 22 to 28 VDC between pump house wire
harness wire 4053 (brown) at water tank drain control valve connector, terminal A and a
known good ground.
If 22 to 28 VDC are not present, troubleshoot Water Tank Drain Valve Does
Not Operate When Selected (WP 0080).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top