TM 9-2320-328-13&P-1
0097-15/(16 blank)
DRAFT
0097
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT0446A
Step 19.
Check for continuity across pump operator’s panel wire harness wire 3895 (black) from
PUMP HOT audio alarm, terminal A to a known good ground.
a.
If there is continuity, replace PUMP HOT PUSH TO TEST switch and
indicator (WP 0218).
b.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION