TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1121 of 1318

TM 9-2320-328-13&P-1
0103-5
DRAFT
0103
Change 1
.
HWT0968
.
Step 6.
Install circuit breaker FS 3 (WP 0242).
Remove cab instrument panel C (WP 0205).
Remove cab instrument panel wire harness F/R LOWER WARNING switch connector.
Push battery disconnect switch to on position (WP 0007).
Turn Service Drive Lights On
(TM 9-2320-422-10).
Put EMERG MASTER switch to on position. (WP 0004).
Check
for 22 to 28 VDC between cab instrument panel wire harness wire 1627 (blue) at F/R
LOWER WARNING switch connector, terminal 6 and a known good ground.
.
If 22 to 28 VDC are present, go to Step 8.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top