TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1128 of 1318

TM 9-2320-328-13&P-1
0103-12
DRAFT
0103
Change 1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3255
.
Step 17.
Install warning lights to original positions (WP 0231).
Put EMERG MASTER and F/R
LOWER WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off
(TM 9-2320-422-10).
Pull battery disconnect switch to off position (WP 0007).
Remove
non-operating front lower warning light (WP 0231).
With a test lead set, check for
continuity across main wire harness wire 1640 (black) from main wire harness warning
light connector, terminal 1 to a known good ground.
.
a.
If there is continuity, repair wire 1610 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
.
b.
If there is no continuity, repair wire 1640 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
.
Step 18.
Put EMERG MASTER and F/R LOWER WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Remove a known operating warning
light.
Remove non-operating rear lower warning light (WP 0231).
Replace
non-operating rear lower warning light with a known operating warning light.
Turn
Service Drive Lights On (TM 9-2320-422-10).
Put EMERG MASTER and F/R LOWER
WARNING switches to on position (WP 0004). Check if known operating warning light
operates in non-operating warning light position.
.
If known operating warning light operates in non-operating warning light
position, replace non-operating warning light (WP 0231).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top