TM 9-2320-328-13&P-1
0103-18
DRAFT
0103
Change 1
.
Step 26.
Put EMERG MASTER and F/R LOWER WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Remove a known operating warning
light.
Remove non-operating front lower warning light (WP 0231).
Replace
non-operating front lower warning light with operating warning light.
Turn Service Drive
Lights On (TM 9-2320-422-10).
Put EMERG MASTER and F/R LOWER WARNING
switch to on position (WP 0004).
Check if known operating warning light operates in
non-operating warning light position.
.
If known operating warning light operates in non-operating warning light
position, replace non-operating warning light (WP 0231).
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3263
.
Step 27.
Put EMERG MASTER and F/R LOWER WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Remove non-operating front lower warning light (WP 0231).
With
a test lead set, check for continuity across main wire harness wire 1640 (black) from
warning light connector, terminal 1 to a known good ground.
.
a.
If there is continuity, repair wire 1611 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
.
b.
If there is no continuity, repair wire 1640 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION