TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1139 of 1318

TM 9-2320-328-13&P-1
0103-23
DRAFT
0103
Change 1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3268
.
Step 32.
Put EMERG MASTER and F/R LOWER WARNING switches to off position (WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Remove passenger side front warning light (WP 0231).
Remove
cab instrument panel A (WP 0196).
Disconnect cab instrument panel wire harness front
and rear warning light flasher connector.
With a test lead set, check for continuity
across wire 1611 (white) from main wire harness warning light connector, terminal 3 to
cab instrument panel wire harness front and rear warning light flasher connector,
terminal 6.
.
If there is continuity, replace front and rear warning light flasher
unit (WP 0196).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top