TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1144 of 1318

TM 9-2320-328-13&P-1
0104-4
DRAFT
0104
Change 1
.
HWT0810
.
Step 5.
Install circuit breaker FS 7 (WP 0242).
Remove cab instrument panel C (WP 0205).
Disconnect cab instrument panel wire harness OVERHEAD WARNING switch
connector.
Push battery disconnect switch to on position (WP 0007).
Turn Service
Drive Lights On (TM 9-2320-422-10).
Put EMERG MASTER switch to on position.
(WP 0004).
With a test lead set, check for 22 to 28 VDC between cab instrument panel
wire harness wire 1629 (green) at OVERHEAD WARNING switch connector, terminal 6
and a known good ground.
.
If 22 to 28 VDC are present, go to Step 7.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top