TM 9-2320-328-13&P-1
0106-6
DRAFT
0106
Change 1
.
HWT0822
.
Step 7.
Put EMERG MASTER switch to off position (WP 0004).
Turn Service Drive Lights Off
(TM 9-2320-422-10).
Pull battery disconnect switch to off position (WP 0007).
Disconnect cab instrument panel wire harness cab power distribution wire harness
connector.
With a test lead set, check for continuity across cab instrument panel wire
harness wire 1648 (yellow) from cab instrument panel wire harness connector, terminal
9 to SIDE WARNING switch connector, terminal 6.
.
a.
If there is continuity, repair wire 1648 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
.
b.
If there is no continuity, repair wire 1648 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0279).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top