TM 9-2320-328-13&P-1
0106-11
DRAFT
0106
Change 1
.
HWT0825
.
Step 15.
Put EMERG MASTER and SIDE WARNING switches to off position (WP 0004).
Turn
Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Remove non-operating side warning light (WP 0231).
With a test
lead set, check for continuity across main wire harness wire 1640 (black) from side
warning light connector, terminal 1 to a known good ground.
.
a.
If there is continuity, repair wire 1651 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
.
b.
If there is no continuity, repair wire 1640 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire harness
(WP 0292).
.
Step 16.
Put EMERG MASTER and SIDE WARNING switches to off position (WP 0004).
Turn
Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Remove one of the side warning lights (WP 0231).
With a test
lead set, check for continuity across main wire harness wire 1640 (black) from side
warning light connector, terminal 1 to a known good ground.
.
If there is no continuity, repair wire 1640 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION