TM 9-2320-328-13&P-1
0056-3
DRAFT
0056
Change 1
..
Step 4.
With hydraulic oil temperature at 125°F (52°C) or greater, check if cab or pump
operator’s panel pressure governor control displays Hydraulic Oil At A Critical
Level (WP 0017).
..
a.
If pressure governor control displays, Hydraulic Oil At A Critical level,
clean hydraulic heat exchanger external cooling fins or replace
hydraulic heat exchanger (WP 0134).
..
b.
If pressure governor control does not display, Hydraulic Oil At A Critical
Level, fault corrected.
..
HWT1122
..
WARNING
..
ICON 3
..
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
..
Step 5.
Remove pump house panel K (WP 0339). Disconnect pump house wire harness fan
temperature switch connector.
With a test lead set, check for 22 to 28 VDC between
pump house wire harness wire 3277 (gray) from fan temperature switch connector,
terminal 1 to a known good ground.
..
If 22 to 28 VDC are present, go to Step 7.
..
MALFUNCTION
TEST OR INSPECTION