TM 9-2320-328-13&P-1
0063-37
DRAFT
0063
HWT2084
WARNING
ICON 26,66
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air line at bumper turret elevation cylinder and
observing air pressure escaping from air line when bumper turret control is activated.
Step 56.
Install bumper turret control cover and tighten four screws.
Disconnect air line at
bumper turret elevation cylinder retract port.
While an assistant operates bumper turret
control joystick to forward position (WP 0004), check if air pressure is present at
bumper turret elevation cylinder retract port.
If air pressure is present, connect air line at bumper turret elevation cylinder
retract port and go to Step 61.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION