0071
HWT1207A
Step 14.
Remove skid plate grille (WP 0349).
Disconnect main wire harness main 1 connector.
With a test lead set, check for continuity across wire 4038 (brown) from pump
operator’s panel PUMP COOLER switch, terminal to main wire harness main 1
connector, terminal 7.
If there is continuity, repair wire 4038 in cab power distribution wire harness
if repairable (TM 9-2320-325-14&P), or replace cab power distribution wire
harness and block (WP 0280).