TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 649 of 1318

TM 9-2320-328-13&P-1
0071-11
DRAFT
0071
HWT1206A
Step 15.
Disconnect main wire harness pump operator’s panel 27-pin wire harness connector.
With a test lead set, check for continuity across main wire harness wire 4038 (brown)
from main wire harness pump operator’s panel 27-pin wire harness connector, terminal
15 to main 1 connector, terminal 7.
a.
If there is continuity, repair wire 4038 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 4038 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top