TM 9-2320-328-13&P-1
0071-20
DRAFT
0071
HWT1200
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 29.
Put pump operator’s panel REEL DISCHARGE switch to OFF position (WP 0004).
Open pump operator’s panel (WP 0207).
With a test lead set, check for 22 to 28 VDC
between pump operator’s panel wire harness wire 2834 (red) at PUMP COOLER
switch, terminal and a known good ground.
If 22 to 28 VDC are not present, repair wire 2834 in pump operator’s panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
Step 30.
Pull battery disconnect switch to off position (WP 0007). While an assistant holds pump
operator’s panel PUMP COOLER switch in ON position, check for continuity across
pump operator’s panel PUMP COOLER switch, from terminal wire 2834 (red) to
terminal wire 4037 (orange).
If there is no continuity, replace pump operator’s panel PUMP COOLER
switch (WP 0221).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION