TM 9-2320-328-13&P-1
0071-25
DRAFT
0071
HWT0540
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 37.
Disconnect pump house wire harness pump cooler valve control connector.
Put cab or
pump operator’s panel PUMP COOLER switch to ON position (WP 0004) and release.
With a test lead set, check for 22 to 28 VDC between pump house wire harness wire
4037 (orange) at pump house wire harness pump cooler valve control connector,
terminal 1 and a known good ground.
If 22 to 28 VDC are not present, repair wire 4037 in pump house wire
harness if repairable (TM 9-2320-325-14&P), or replace pump house wire
harness.
Step 38.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 2200 (black) from pump house wire harness pump cooler valve
control connector, terminal 2 to a known good ground.
a.
If there is continuity, replace pump cooler control valve (WP 0271).
b.
If there is no continuity, repair wire 2200 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION