TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 668 of 1318

TM 9-2320-328-13&P-1
0072-4
DRAFT
0072
Change 1
..
HWT0700
..
NOTE
During initialization of pressure governor system, pressure governor control splash screen
will display Pierce Manufacturing’s emblem.
If issues are found during initial power up
sequence, system errors or warning will be logged and appropriate indicator will be
activated on home screen.
System operations may be degraded, when pressure governor WARNING! and
CAUTION! are active.
All system WARNING! and CAUTION! should be cleared before
operations are continued.
Some system warnings will bring water pump operations to idle.
If water pump operations
are brought to idle, do not attempt to restart operations until all WARNING! and CAUTION!
are cleared.
WARNING! and CAUTION! indicator will be displayed until conditions are cleared.
Some faults will be accompanied by four “wild card” symbols (
****
) in display section of
pressure governor control that is affected by fault.
..
Step 6.
Start engine (TM 9-2320-422-10).
At pump operator’s panel, check if pressure
governor control displays WARNING! indicator in Engine RPM location of Home
screen (WP 0017).
..
If pump operator’s panel pressure governor does not displays a WARNING!
fault, go to Step 9.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top