TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 669 of 1318

TM 9-2320-328-13&P-1
0072-5
DRAFT
0072
Change 1
..
HWT0816
..
NOTE
Warning events initiate when a critical system failure or limit has occurred.
A critical
system is defined as a part or system that may cause the fire apparatus to stop flowing
water immediately if no action is taken.
Active WARNING! faults are displayed on home diagnostic screen with an “X” in Act
(active) column.
Inactive WARNING! faults are displayed on home diagnostic screen with a “—” in Act
(active) column.
..
Step 7.
If pressure governor displays WARNING!, perform the following to display
warnings (WP 0018).
..
a.
Press home button to display home diagnostic screen (WP 0004).
..
b.
Press OK button to acknowledge warning and view details of
fault (WP 0004).
..
c.
Record warning.
..
d.
Press return button to view home diagnostic screen.
..
e.
If more than one WARNING! fault has occurred, press scroll up/down
button to select next occurring WARNING! fault.
..
f.
Press OK button to acknowledge warning and view details of fault.
..
g.
Record warning fault.
..
h.
Repeat Steps (d) through (g) above, until home screen is displayed.
..
i.
With warning fault(s) recorded, go to Step 8.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top