TM 9-2320-328-13&P-1
0071-24
DRAFT
0071
HWT1198
WARNING
ICON 26,66
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air lines at pump cooler valve and observing air
pressure escaping from air line, when pump cooler control valve is activated.
Air will
escape from blue air line when PUMP COOLER switch is put to ON position, and escape
from red air line when PUMP COOLER switch is put to OFF position.
System air pressure
may drop below 85 psi (586 kPa) during this procedure.
Step 36.
Disconnect air lines at pump cooler valve.
While an assistant puts cab or pump
operator’s panel PUMP COOLER switch to ON and OFF positions (WP 0004), check if
air pressure is present at pump cooler valve.
If there is air pressure, replace pump cooler valve (WP 0319).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION