Step 34.
Put cab PUMP COOLER switch to off position (WP 0004) and release.
Put pump
operator’s panel REEL DISCHARGE switch to ON position (WP 0004).
Check if
REEL
DISCHARGE indicator illuminates.
If REEL DISCHARGE indicator does not illuminate, go to Step 39.
HWT0539
Step 35.
Put REEL DISCHARGE switch to OFF position (WP 0004).
Inspect air lines from air
control valve manifold to pump cooler valve for kinks and damage.
If air lines are kinked or damaged, replace damaged air lines (WP 0374).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION