Step 4.
Check if pump operator’s panel pressure governor control display contrast,
brightness, and backlighting adjustments, are set to allow indication of system
operations (WP 0017).
..
If adjustments are set to allow indication of system operations, go to Step 6.
..
NOTE
Contrast can be set by user ranging from 0% to 100%.
Default setting is 50%.
Brightness can be set by user ranging from 0% to 100%.
Default setting is 50%.
Backlighting can be set by user ranging from 0% to 100%.
Default setting is 50%.
..
Step 5.
At pump operator’s panel pressure governor control, press back button to display menu
selection screen (WP 0017).
Press scroll up/down button until SETTINGS is selected
(WP 0017).
Press OK button (WP 0017).
Adjust pump operator’s panel pressure
governor control contrast, brightness, and backlighting for suitable display.
Press back
button until home screen is displayed (WP 0017).
..
a.
If pump operator’s panel governor control cannot be adjusted to a
usable display, replace pump operator’s panel pressure governor
control (WP 0197).
..
b.
If adjustments are made and pump operator’s panel pressure governor
control functions properly, fault has been corrected, notify Supervisor.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION