TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 694 of 1318

TM 9-2320-328-13&P-1
0072-30
DRAFT
0072
Change 1
..
HWT2661
..
Step 35.
Turn ENGINE switch to OFF position (TM 9-2320-422-10).
Pull battery disconnect
switch to off position (WP 0007).
Disconnect pump operator’s panel wire harness
pressure governor control connector (WP 0216).
Disconnect main wire harness cab
pressure governor control connector (WP 0197).
With a test lead set, check for
continuity across CAN Hi wire (yellow) from main wire harness cab pressure governor
control connector, terminal 50 to pump operator’s panel wire harness pressure governor
control connector, terminal 50.
..
If there is continuity, go to Step 40.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top